Emerson Process Management 51000 Manuale Utente

Navigare online o scaricare Manuale Utente per no Emerson Process Management 51000. Emerson Process Management 51000 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 8
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
1
Baumann
51000 Series Instructions
Instruction
51.LF:IM
April 2007
INTRODUCTION
The Baumann 51000 series control valve is optimally
designed for demanding low ow control and is a
perfect t where space is at a premium. This compact
package provides the connection integrity of anged
body globe valves while being signi cantly lighter and
easier to install.
SCOPE OF MANUAL
This instruction manual includes installation,
maintenance, and parts information for the 51000
series control valve and type 16 actuator.
No person may install operate or maintain a 51000
series control valve without rst being fully trained and
quali ed in valve, actuator and accessory installation,
operation and maintenance, and carefully reading and
understanding the contents of this manual. If you have
any questions about these instructions contact your
Fisher
®
sales of ce before proceeding.
CONTENTS
Introduction.................................................................1
Scope......................................................................1
Safety Precautions..................................................1
Maintenance...............................................................2
Installation...................................................................3
Actuator Removal....................................................3
Plug and Packing Replacement..............................3
Disassembly of Valve..............................................3
Reassembly of Valve...........................................3
Body Assembly Part Numbers...............................4
Type 16 Actuator Part Numbers...........................6
Dimensions and Weights............................................7, 8
Always wear protective gloves,
clothing, and eye wear when
performing any installation operations
to avoid personal injury.
Personal injury or property damage
caused by sudden release of pressure
or bursting of pressure retaining parts
may result if service conditions exceed
those for which the product was
intended. To avoid injury or damage,
provide relief valve for over pressure
protection as required by government
or accepted industry codes and good
engineering practices.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
If installing into an existing application,
also refer to the WARNING at the
beginning of the Maintenance section
in this instruction manual.
This valve is intended for a speci c
range of pressures, temperatures
and other application speci cations.
Applying different pressures and
temperatures to the valve could
result in parts damage, malfunction
of the control valve or loss of control
of the process. Do not expose this
product to service conditions or
variables other than those for which
the product was intended. If you
are not sure what these conditions
are you should contact your Fisher
sales of ce for more complete
speci cations. Provide the product
serial numbers (shown on the
nameplate) and all other pertinent
information.
NOTE
Neither Emerson
®
, Emerson Process
Management, Fisher
®
, nor any of
their af liated entities assumes
responsibility for the selection, use
and maintenance of any product.
Responsibility for the selection, use
and maintenance of any product
remains with the purchaser and end-
user.
Baumann
51000 Series Low Flow
Control Valve Instructions
:$51,1*
:$51,1*
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - Control Valve Instructions

1Baumann™ 51000 Series InstructionsInstruction51.LF:IMApril 2007INTRODUCTIONThe Baumann 51000 series control valve is optimally designed for demanding

Pagina 2 - 51000 Series Instructions

2Instruction51.LF:IMApril 2007Baumann™ 51000 Series InstructionsIf you move or work on an actuator installed on a valve with loading pressure applied,

Pagina 3

3Baumann™ 51000 Series InstructionsInstruction51.LF:IMApril 2007INSTALLATION1. Before installing the valve in the pipeline, thoroughly clean the line

Pagina 4

4Instruction51.LF:IMApril 2007Baumann™ 51000 Series InstructionsKEY NO.DESCRIPTION QTYPART NUMBER0.25" SS0.25" N10276 Nickel Alloy0.5"

Pagina 5

5Baumann™ 51000 Series InstructionsInstruction51.LF:IMApril 2007bonnet - confi rm correct orientation - then secure with hex nuts (7). DO NOT TIGHTEN

Pagina 6

6Instruction51.LF:IMApril 2007Baumann™ 51000 Series InstructionsTable 4. TYPE 16 ACTUATOR PART NUMBERSKEY NO.QTY DESCRIPTION PART NUMBER17 1 Yoke - M

Pagina 7

7Baumann™ 51000 Series InstructionsInstruction51.LF:IMApril 2007Table 5. DIMENSIONS AND WEIGHTS, BODY SUBASSEMBLYVALVE SIZE AMATERIALAPPROXIMATE WEIG

Pagina 8

8Instruction51.LF:IMApril 2007Baumann™ 51000 Series InstructionsACTUATOR TYPEINSTRUMENTAPPROXIMATE WEIGHTlbs kg16Actuator without instrument 4.0 1.8Ty

Commenti su questo manuale